Abricon Homepage
Home About Us Our Services Case Studies Knowledge Store Contact
Brownfield & Waste
Slope Stability and Contamination Investigation, South Wales
 
Development of a Civil Amenity Contract, Waste Management, Devon
 
Tank Pull, Geotechnical & Contamination Investigation of a Former Garage, UK
 
Investigation and Remediation of a Site for Residential Development, UK
 
Groundwater Remediation VOC contamination, UK
 
Site Investigation of a Former Filling Station, UK
 
Phase 1 Desk Study of a Former Dairy farm, UK
 
Phase 1 Desk Study, Olympia, London
 
IPPC and Remediation, Electroplating Facility, UK
 
Exemption from a Waste Management Licence, UK
 
SEIC Waste Study, Russian Fed
 
Aviation Fuel Pipeline Contract, Major UK Airport
 
Brownfield, Waste & Geotechnical Environmental Compliance Resource Efficiency Ecological Solutions
Case Studies - Brownfield, Waste & Geotechnical

Site Investigation of a Former Filling Station

Client: Fleet Field Services
Location: Digbeth, Birmingham
Date: 2007
Project: Investigation of a Former Petrol Station Site

Our client required us to carry out an investigation the site prior to sale to limit liabilities that may arise from contamination arising from previous usage. The site had been used as a filling station until 20 years ago when our client bought the site and used it for car servicing.


A desk study and walkover survey was carried out initially that indicated that widespread contamination of the site was unlikely to have occurred unless there had been leakage form the tanks. Based on this, a limited phase II inve investigation was carried out to assess contamination in soils in the area of the tanks.


The investigation showed no contamination of the soilswith hydrocarbons although some metals were present due to previous site uses. However, the conceptual site model indicated that there were no reasonable pathways to human health or groundwater receptors.

The report concluded that unless there was a change of use that introduced new pathways, the site posed no risk to human health or groundwater receptors.